This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Skip booklet index and go to page content

Code of Practice for the Management of Fine Particulate Matter (PM2.5) Emissions in the Potash Sector in Canada

Annexes

Annex A: Recordkeeping template (refer to section 5.1.4)

Facilities may choose to use this template to assess initial conditions and for review purposes. The table lists the Code’s recommendations with associated parameters.

Facility

Contact information

Table 1. Code recommendations with associated parameters
Recommendation
Parameters
Monitoring frequency
Normal operating range
Daily value recorded
(unless otherwise specified)
Date
Indicate whether reading is within range
Yes
Indicate whether reading is within range
No
R01 - venturi scrubbersgas flow ratecontinuous     
R01 - venturi scrubbersgas pressure dropcontinuous     
R01 - venturi scrubberswater/brine flow ratecontinuous     
R01 - venturi scrubbersfan amperagecontinuous     
R01 - venturi scrubbersL/G ratiocalculate daily     
R02 - non-venturi scrubbersgas flow ratecontinuous     
R02 - non-venturi scrubberswater/brine flow ratecontinuous     
R02 - non-venturi scrubbersnozzle pressurecontinuousconsult manufconsult manuf   
R02 - non-venturi scrubbersfan amperagecontinuous     
R02 - non-venturi scrubbersL/G ratiocalculate daily     
R04 - brine recirculating systemsbrine specific gravityweekly     
R05 - baghousesgas pressure dropcontinuous     
R05 - baghousesfan amperageContinuous     
R06 - baghousesBLDS voltageContinuous     
R08 - ESPssecondary currentContinuous     
R08 - ESPssecondary voltageContinuous     
R08 - ESPsspark rateWeeklyconsult manufconsult manuf   

R10 Excursions - emission control device

Excursion noted on device
Specify device and excursionDate
  
  
  
  

 

Excursion correction
Type of correction implementedDate
  
  
  
  

 

Maintenance practicesStatus of system or deviceFollow-up actions if requiredDate
R03 - wet scrubbers   
system leaks   
corrosion   
pump, piping, pressure gauges   
R07 - baghouses   
pressure taps   
triboelectric probe   
fans   
bag cleaning mechanism   
bags   
R9 - ESPs   
power consumption   
dust concentration at exit   
plates/tubes/wires   
R11 - cyclones   
dust collection at exit   
corrosion, plugging   
cyclone design   
air lock   
R12 - general facility   
dryer air discharge system   
R13 - general facility   
compactor hoods and ducting   
R14- general facility   
materials handling processes   

 

R15 Environmental management practices - general facilityStatus of implementationDate
Environmental management practices - list  

Annex B: Sample report template

Part A: Emissions reporting

Facilities are asked to report their PM2.5 emissions as well as the measurement method used to quantify those emissions in a table similar to the format provided below.

Annual reporting of PM2.5 emissions
Source of PM2.5Annual quantity of PM2.5 emitted (tonnes)Quantification methodology
Stack/Dryers  
Stack/Compactors  
Storage or handling  
Fugitive  
Other non-point  
Road dust  
Total quantitiy emitted (t)  

Part B: Reporting on the implementation of the code of practice

The following provides a list of sample questions which may be used to demonstrate facility progress towards implementation of the Code.  For each recommendation in this Code, facilities are asked to provide answers to the following questions:

  • Has the facility implemented the recommendation?
  • If the answer is yes, please describe how the facility has implemented the recommendation.
  • If the answer is no, please explain whether the facility plans to implement the recommendation. 
  • If the facility plans to implement the recommendation at a later date, please explain what will be done and by what date.
  • If the facility does not plan to implement the recommendation, please explain why and also describe what practices the facility has in place to ensure the optimal operation of the specified control device. 

Facilities should provide, if needed, any additional information on each recommendation.

Part C: Declaration

A declaration, as per the example below, is to be attached to each report.

I declare that this report is true, accurate and complete.

 

_________________________________
Operator’s name (please print)

_________________________________
Position title

 

_________________________________
Telephone

_________________________________
Email

 

_________________________________
Operator’s signature

_________________________________
Date of signature

Page 10
Date modified: