Table 5 Daily, Quarterly, Semi-annual and Annual Performance Evaluations Summary
| Parameter | Component | Level | Specification | References | |
|---|---|---|---|---|---|
| Specifi-cations | Test Procedures | ||||
| Daily performance evaluations | |||||
| 24-hour calibration drift | CO2 (or O2) analyzer | Low level (0–20% FS) High level (80–100% FS) Out-of-control condition |
≤ 0.5% CO2 (or O2) ≤ 0.5% CO2 (or O2) Exceedance of twice the above levels |
6.2.1 | 5.3.2/6.2.1 |
| Stack gas moisture monitor* – wet O2 /Temp./RH System | Low level (0–20% FS) High level (80–00% FS) Out-of-control condition |
≤ 0.5% O2 ≤ 0.5% O2 Exceedance of twice the above levels |
|||
| Flow monitor with system calibration capability | Low level (0–20% FS) High level (80–00% FS) Out-of-control condition |
≤ the greater of 3.0% FS or 0.6 m/s absolute difference 3.0% FS or 0.6 m/s absolute difference Exceedance of twice the above levels |
|||
| Flow monitor without system calibration capability | Electronic reference level Out-of-control condition |
≤ 3.0% FS Exceedance of twice the above levels |
6.2.2 | ||
| Quarterly performance evaluations | |||||
| Cylinder gas test | CO2 (or O2) analyzer (Note: alternative provisions for certain types of in situ analyzers in 6.3.1.7) | Low level (0–20% FS) Mid level (40–60% FS) High level (80–100% FS) Out-of-control condition |
≤ 1.0% CO2 (or O2) ≤ 1.0% CO2 (or O2) ≤ 1.0% CO2 (or O2) Exceedance of the above levels |
6.3.1 | 6.3.1 |
| Stack gas moisture monitor* – wet O2 /Temp./RH System | Low level (0–20% FS) Mid level (40–60% FS) High level (80–100% FS) Out-of-control condition |
≤ 1.0% O2 ≤ 1.0% O2 ≤ 1.0% O2 Exceedance of the above levels |
|||
| Stack gas flow test | Alternatives: – Flow-to-output evaluation – Heat-to-output evaluation – Abbreviated flow-to-output test – Abbreviated heat-to-output test – Flow RM test |
Representative load level Representative load level Representative load level Representative load level Representative load level Out-of-control condition |
≤ 10% absolute difference, output ≥ 60 MJ/s ≤ 15% absolute difference, output < 60 MJ/s ≤ 10% absolute difference, output ≥ 171 MJ/s ≤ 15% absolute difference, output < 171 MJ/s ≤ 10% absolute difference, output ≥ 60 MJ/s ≤ 15% absolute difference, output < 60 MJ/s ≤ 10% absolute difference, output ≥ 171 MJ/s ≤ 15% absolute difference, output < 171 MJ/s ≤ the greater of 6.0% FS or 1.2 m/s Exceedance of the above levels |
6.3.2 | 6.3.2 |
| Semi-annual performance evaluations | |||||
| Relative accuracy (RA) | CO2 (or O2) analyzer | Representative load level Out-of-control condition |
≤ the greater of 10.0% RA or 0.5% CO2 (or O2) avg. absolute difference Exceedance of the above levels |
6.4.1 | 5.3.4/6.4.1 |
| Stack gas moisture monitor* | Representative load level Out-of-control condition |
≤ the greater of 10.0% RA or 2.0% of (100 - Bws) avg. absolute difference Exceedance of the above levels |
|||
| Flow monitor | Representative load level Out-of-control condition |
≤ the greater of 10.0% RA or 0.6 m/s avg. absolute difference Exceedance of the above levels |
|||
| CO2 mass emission | Representative load level Out-of-control condition |
≤10.0% RA Exceedance of the above levels |
|||
| Bias | CO2 (or O2) analyzer | Representative load level Out-of-control condition |
≤ the greater of 5.0% of FS value or 0.5% CO2 (or O2) avg absolute difference Exceedance of the above levels |
6.4.1 | 5.3.5/6.4.1 |
| Stack gas moisture monitor* | Representative load level Out-of-control condition |
≤ the greater of 5.0% RA or 1.0% of (100-Bws) avg absolute difference Exceedance of the above levels |
|||
| Flow monitor | Representative load level Out-of-control condition |
≤ the greater of 5.0% of FS value or 0.6 m/s avg. absolute difference Exceedance of the above levels |
|||
| Annual performance evaluations | |||||
| Relative accuracy (RA) | CO2 (or O2) analyzer | Representative load level Out-of-control condition |
≤ the greater of 10.0% RA or 0.5% CO2 (or O2) avg. absolute difference Exceedance of the above levels |
6.4.1 | 5.3.4/6.4.1 |
| Stack gas moisture monitor* | Representative load level Out-of-control condition |
≤ the greater of 10.0% RA or 2.0% of (100 - Bws) avg. absolute difference Exceedance of the above levels |
|||
| Flow monitor | Representative load level Out-of-control condition |
≤ the greater of 10.0% RA or 0.6 m/s avg. absolute difference Exceedance of the above levels |
|||
| CO2 mass emission | Representative load level Out-of-control condition |
≤10.0% RA Exceedance of the above levels |
|||
| Bias | CO2 (or O2) analyzer | Representative load level Out-of-control condition |
≤ the greater of 5.0% of FS value or 0.5% CO2 (or O2) avg absolute difference Exceedance of the above levels |
6.4.1 | 5.3.5/6.4.1 |
| Stack gas moisture monitor* | Representative load level Out-of-control condition |
≤ 5.0% of FS (100 - Bws) value Exceedance of the above levels |
|||
| Flow monitor | Representative load level Out-of-control condition |
≤ the greater of 5.0% of FS value or 0.6 m/s avg. absolute difference Exceedance of the above levels |
|||
| Availability | Non-peaking EGUs Peaking EGUs |
– | ≥ 90% annually in first year ≥ 95% annually thereafter ≥ 80% annually |
6.5.1 | 6.5.1 |
| Independent Auditing | – | – | Evaluation by an independent auditor | 6.5.2 | – |
* The performance specifications for stack gas moisture based on wet O2 measurements (calibration drift, response time, relative accuracy, and availability) are summarized in Table 3 and Table 5. Other moisture monitoring systems may be used to correct dry measured concentrations, if it is demonstrated that the system is able to calculate the hourly factor (100 - Bws) with an error ≤2.0% all year round. The specific QA activities related to the moisture monitoring system must then be described in the QA/QC manual. Further details on the use of stack gas moisture monitoring systems are presented in Section 7. Note that Bws is the moisture content of the stack gas (in % of volume)